FORMULA OF CALCULATING WEIGHT :
- Weight of S.S. Pipe
O.D. (mm) – W. Thick (mm) x W. Thick (mm) x 0.0248 = Wt. Per Mtr.
O.D. (mm) – W. Thick (mm) x W. Thick (mm) x 0.00756 = Wt. Per Feet. - Weight of S.S. Round Bar
DIA (mm) x DIA (mm) x 0.00623 = Wt. Per Mtr.
DIA (mm) x DIA (mm) x 0.0019 = Wt. Per Feet. - Weight of S.S. Square Bar
DIA (mm) x DIA (mm) x 0.00788 = Wt. Per Mtr.
DIA (mm) x DIA (mm) x 0.0024 = Wt. Per Feet. - Weight of S.S. Hexagonal Bar
DIA (mm) x DIA (mm) x 0.002072 = Wt. Per Feet. - Weight of S.S. Flat Bar
Width (mm) x Thick (mm) x 0.00243 = Wt. Per Feet. - Weight of S.S. Sheets & Plates
Length (Feet) x Width (Feet) x Thick (mm) x 3/4 = Wt. Per PC - Weight of S.S. Circle
DIA (mm) x DIA (mm) x Thick (mm) x 0.0000063 = Kg. Per PC - Weigth of Brass Pipe / Copper Pipe
O.D. (mm) – Thick (mm) x Thick (mm) x 0.0260 = Wt. per Mtr. - Weight of Lead Pipe
O.D. (mm) – Weight (mm) x Weight (mm) x 0.0345 = Wt. per Mtr. - Weight of Aluminium Pipe
O.D. (mm) – Thick (mm) x Thick (mm) x 0.0083 = Wt. per Mtr. - Weight of Aluminium Sheet
Length (Mtr.) x Width (Mtr.) x Thick (mm) x 2.69 = Wt. Per PC - Weight Conversion of Mtr. To Feet
Weight per Mtr. 3.2808 = Wt. oer Ft. - Barlow’s Formula for Calculating Bursting Pressure
P = 2ST/D or T-DP/2S or S-DP/2T or D = 2ST / P
P = Bursting Pressure P SI
S = Tensile Strength of Tube
T = Wall Thickness ( In inches)
D = Outside Diameter (In inches)